Skip to content

Reference and Data

Use this chapter when you need a conversion, a Hamiltonian, a selection rule, or the meaning of a spectroscopic quantity. The reference pages give compact answers with their assumptions and link to fuller explanations. A table is most useful when you can tell which physical quantity it describes: an angular frequency is not an ordinary frequency, and a symmetry-allowed transition need not produce a visible line.

Question Reference page
How do I convert energy, frequency, wavelength, and temperature-equivalent energy? Constants and conversions, atomic units
Which degrees of freedom and interactions should my model retain? AMO model index
What terms enter a Hamiltonian, and when do they apply? Atomic Hamiltonians, molecular Hamiltonians
What do level labels and transition rules mean? Term symbols, selection rules
How do I relate a matrix element to a transition strength or decay rate? Oscillator strengths, Einstein coefficients
Which line width or spectral coordinate am I using? Line shapes, spectroscopy nomenclature
How are laser, cavity, and drive parameters defined? Laser nomenclature
Where should I start reading about an experiment or a subject? AMO experiment index, bibliography and reading guide

The broader Reference collection connects these topics to operators, mathematical identities, models, and conventions used throughout quantum mechanics.

For a photon in vacuum,

E=hν=ℏω=hcν~,ω=2πν,ν~=1λvac.E=h\nu=\hbar\omega=hc\tilde\nu, \qquad \omega=2\pi\nu,\qquad \tilde\nu=\frac{1}{\lambda_{\mathrm{vac}}}.

Here ν\nu is ordinary frequency in hertz, ω\omega is angular frequency, and ν~\tilde\nu is spectroscopic wavenumber. If the wavelength is in metres, the inverse wavelength is in m−1\mathrm{m^{-1}}; divide its numerical value by 100100 to express the same wavenumber in cm−1\mathrm{cm^{-1}}. The vacuum wavevector magnitude is k=2πν~k=2\pi\tilde\nu.

The energy-equivalent temperature TE=E/kBT_E=E/k_{\mathrm B} is another way to state a scale. It is not automatically the thermodynamic temperature of an ensemble. Likewise, setting ℏ=me=e=4πϵ0=1\hbar=m_e=e=4\pi\epsilon_0=1 in Hartree atomic units changes the numerical representation of quantities, not their physical dimensions. Atomic units and scales derives the associated length, energy, time, and field units.

For a spectral line in a medium, use its frequency and the appropriate phase refractive index to relate in-medium and vacuum wavelengths. An air wavelength cannot be substituted for λvac\lambda_{\mathrm{vac}} without that conversion. The BIPM SI Brochure defines the units, while a named CODATA adjustment supplies measured constants and their correlated uncertainties. The 2022 adjustment is described by Mohr et al. (2025).

Line widths: population, coherence, and frequency

Section titled “Line widths: population, coherence, and frequency”

For an isolated radiative two-level transition with a stable ground state, no pure dephasing, and no driving field, let

Pe(t)=Pe(0)e−Γt,τ=Γ−1.P_e(t)=P_e(0)e^{-\Gamma t},\qquad \tau=\Gamma^{-1}.

The optical coherence decays at Γ/2\Gamma/2. The corresponding Lorentzian natural line has angular-frequency HWHM Γ/2\Gamma/2, angular-frequency FWHM Γ\Gamma, and ordinary-frequency FWHM

ΔνFWHM=Γ2π=12πτ.\Delta\nu_{\mathrm{FWHM}}=\frac{\Gamma}{2\pi} =\frac{1}{2\pi\tau}.

These different widths describe the same ideal line. Pure dephasing increases coherence decay without the same increase in population decay. Decay of both levels, strong driving, Doppler broadening, or instrument response also changes the simple correspondence. Line shapes and broadening develops these distinctions; Bernath and Demtröder provide textbook treatments.

Allowed transitions and observable strengths

Section titled “Allowed transitions and observable strengths”

A selection rule gives a condition under which a matrix element Mfi=⟨f∣O^∣i⟩\mathcal M_{fi}=\langle f|\hat O|i\rangle must vanish. Passing that condition does not determine the matrix element’s size. Radial cancellation, state mixing, initial populations, polarization, and the detector can all make an allowed transition weak or absent.

Before converting an oscillator strength, Einstein coefficient, or line strength, check whether it is summed over final magnetic substates and averaged over initial ones. Also match polarization and ordinary-frequency versus angular-frequency spectral density. Degeneracy factors often account for an apparent disagreement between two formulas.

Level labels require the same care. In a weak-field coupling regime, FF may be a useful hyperfine quantum number; in a stronger field it can become only an approximate label. Term symbols distinguishes exact symmetry labels from labels for a dominant component.

From transition lines to a measured spectrum

Section titled “From transition lines to a measured spectrum”

For an incoherent sum of lines in a linear detection regime, a useful model is

Strue(x)=∑jAjϕj(x−xj),S_{\mathrm{true}}(x)=\sum_j A_j\phi_j(x-x_j),

where xjx_j is a line position, AjA_j its integrated weight, and each ϕj\phi_j is normalized in the spectral coordinate xx. Different transitions can have different widths. A general linear instrument response gives

Sobs(x)=∫K(x,x′)Strue(x′) dx′+B(x).S_{\mathrm{obs}}(x)=\int K(x,x')S_{\mathrm{true}}(x')\,dx'+B(x).

Only when K(x,x′)=R(x−x′)K(x,x')=R(x-x') does the integral become a convolution. Only when all physical profiles are the same can the true spectrum itself be written as one stick spectrum convolved with a common profile. Coherent interference, saturation, or a nonlinear detector may require a different forward model.

In transmission experiments the instrument averages transmitted intensity. Taking a logarithm after this average generally differs from convolving the absorbance itself. With transmittance T=I/I0T=I/I_0,

OD=−ln⁡T,A10=−log⁡10T,OD=(ln⁡10)A10.\mathrm{OD}=-\ln T,\qquad A_{10}=-\log_{10}T, \qquad \mathrm{OD}=(\ln10)A_{10}.

The symbol OD is not universal: some laboratory conventions use it for a base-ten quantity. Define it by an equation. The spectroscopy nomenclature page connects these definitions to cross sections and integrated intensities.

The NIST Atomic Spectra Database provides evaluated atomic levels, wavelengths, and transition probabilities. Read each entry’s uncertainty, accuracy flags, and source references; a value may come from measurement, calculation, or an evaluation combining several results. The NIST Chemistry WebBook collects molecular spectra and thermochemical data. The IUPAC Gold Book defines terminology.

For a number you will use in a calculation, keep the source version or access date, isotope and charge state, level labels, units, uncertainty, and any air/vacuum convention. Include the original reference attached to a database entry. A hyperfine-resolved wavelength in an external field and a calculated fine-structure centroid may both be correct while referring to different quantities.

A measured or fitted number has uncertainty even when many digits are printed. For a small standard uncertainty uxu_x, a smooth conversion y=f(x)y=f(x) gives uy≃∣f′(x)∣uxu_y\simeq|f'(x)|u_x. In particular, for a positive vacuum wavelength and ν=c/λ\nu=c/\lambda,

uν≃cλ2uλ,uνν≃uλλ.u_\nu\simeq\frac{c}{\lambda^2}u_\lambda, \qquad \frac{u_\nu}{\nu}\simeq\frac{u_\lambda}{\lambda}.

The absolute uncertainty changes its units and magnitude. Multiple uncertain inputs require their covariance; large relative uncertainties may require nonlinear propagation. Precision metrology explains these methods.

A transition is reported as a cyclic frequency ν\nu. State the equations needed to express it as angular frequency, photon energy, and spectroscopic wavenumber.

Solution

Use

ω=2πν,E=hν,ν~=νc.\omega=2\pi\nu, \qquad E=h\nu, \qquad \tilde\nu=\frac{\nu}{c}.

The last relation gives inverse metres; divide by 100100 to express the result in cm−1\mathrm{cm^{-1}}. The symbol ν~\tilde\nu is spectroscopic wavenumber, not the wavevector magnitude k=2πν~k=2\pi\tilde\nu.

An E1 transition passes the angular-momentum and parity rules but is absent from a measured spectrum. List four checks before calling the selection rule wrong.

Solution

Check the reduced and radial matrix elements or configuration mixing; initial population; polarization and geometry; branching and competing decay; line overlap or broadening; detector sensitivity; and whether the assigned quantum numbers remain valid in the applied fields. Selection rules are normally necessary conditions, not guaranteed line-strength predictions.

One source defines Γ\Gamma through population decay, while another calls γ\gamma the optical-coherence HWHM in angular frequency. Can the symbols be equated directly?

Solution

No. Derive the coherence equation in each convention. For an isolated radiative two-level system without pure dephasing, the coherence decays at Γ/2\Gamma/2, but extra dephasing changes that relation. Also verify whether the reported width is HWHM or FWHM and whether it uses ω\omega or ν\nu.